ADVERSE REACTIONS SECTION.
ADVERSE REACTIONS. The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in an approximate decreasing order of occurrence: burning, itching, irritation, dryness, folliculitis, hypertrichosis, acneiform eruptions, hypopigmentation, perioral dermatitis, allergic contact dermatitis, maceration of the skin, secondary infection, skin atrophy, striae, miliaria. To report SUSPECTED ADVERSE REACTIONS, contact G&W Laboratories, Inc. at 1-800-922-1038 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.
Citing DrugCentral © 2024. License
CLINICAL PHARMACOLOGY SECTION.
CLINICAL PHARMACOLOGY. Topical corticosteroids share anti-inflammatory, antipruritic and vasoconstrictive actions. The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man. Pharmacokinetics: The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings. Topical corticosteroids can be absorbed from normal intact skin. Inflammation and/or other disease processes in the skin increase percutaneous absorption. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be valuable therapeutic adjunct for treatment of resistant dermatoses. (See DOSAGE AND ADMINISTRATION.) Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.
Citing DrugCentral © 2024. License
CONTRAINDICATIONS SECTION.
CONTRAINDICATIONS. Fluocinonide cream is contraindicated in those patients with history of hypersensitivity to any of the components of the preparation.
Citing DrugCentral © 2024. License
DESCRIPTION SECTION.
DESCRIPTION. Fluocinonide Cream, USP 0.05% is intended for topical administration. The active component is the corticosteroid fluocinonide, which is the 21-acetate ester of fluocinolone acetonide and has the chemical name pregna-1,4-diene-3,20-dione, 21-(acetyloxy)-6,9-difluoro-11-hydroxy-16,17-[(1-methylethylidene)bis(oxy)]-, (6,11ss,16). Its molecular formula is C26H32F2O7, and has the molecular weight of 494.53. It has the following chemical structure: Fluocinonide Cream, USP 0.05% contains fluocinonide 0.5 mg/g in cream base consisting of citric acid, 1,2,6-hexanetriol, polyethylene glycol-8000, propylene glycol and stearyl alcohol. This white cream vehicle is greaseless, non-staining, anhydrous and completely water miscible. The base provides emollient and hydrophilic properties. In the Fluocinonide Cream, USP 0.05% formulation, the active ingredient is totally in solution.. structural formula.
Citing DrugCentral © 2024. License
DOSAGE & ADMINISTRATION SECTION.
DOSAGE AND ADMINISTRATION. Fluocinonide cream 0.05% is generally applied to the affected area as thin film from two to four times daily depending on the severity of the condition. Occlusive dressings may be used for the management of psoriasis or recalcitrant conditions. If an infection develops, the use of occlusive dressings should be discontinued and appropriate antimicrobial therapy instituted.
Citing DrugCentral © 2024. License
HOW SUPPLIED SECTION.
HOW SUPPLIED. Fluocinonide Cream, USP 0.05% is supplied in 15 tubes. Store at 20-25C (68-77F) [see USP Controlled Room Temperature]. Repackaged by:Aidarex Pharmaceuticals, LLCCorona, CA92880Manufactured by:G&W Laboratories, Inc.111 Coolidge Street South Plainfield, NJ 07080Distributed by: Mayne PharmaGreenville, NC 27834 Rev. 02/20168-0663MN1.
Citing DrugCentral © 2024. License
INDICATIONS & USAGE SECTION.
INDICATIONS AND USAGE. Fluocinonide Cream, USP 0.05% is indicated for the relief of the inflammatory and pruritic manifestations of corticosteroid-responsive dermatoses.
Citing DrugCentral © 2024. License
OVERDOSAGE SECTION.
OVERDOSAGE. Topically applied corticosteroids can be absorbed in sufficient amount to produce systemic effects (see PRECAUTIONS).
Citing DrugCentral © 2024. License
PACKAGE LABEL.PRINCIPAL DISPLAY PANEL.
PRINCIPAL DISPLAY PANEL. 33261-0560FLUOCINONIDE15G. 33261-0560FLUOCINONIDE15G.
Citing DrugCentral © 2024. License
PRECAUTIONS SECTION.
PRECAUTIONS. General: Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushings syndrome, hyperglycemia, and glucosuria in some patients. Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings. Therefore, patients receiving large dose of potent topical steroid applied to large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application, or to substitute less potent steroid. Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids. Children may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity. (See PRECAUTIONS-Pediatric Use.) If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted. As with any topical corticosteroid product, prolonged use may produce atrophy of the skin and subcutaneous tissues. When used on intertriginous or flexor areas, or on the face, this may occur even with short term use. In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled. Information for the Patient: Patients using topical corticosteroids should receive the following information and instructions:1. This medication is to be used as directed by the physician. It is for external use only. Avoid contact with the eyes.2. Patients should be advised not to use this medication for any disorder other than for which it was prescribed.3. The treated skin area should not be bandaged or otherwise covered or wrapped as to be occlusive unless directed by the physician.4. Patients should report any signs of local adverse reactions especially under occlusive dressing.5. Parents of pediatric patients should be advised not to use tight-fitting diapers or plastic pants on child being treated in the diaper area, as these garments may constitute occlusive dressings. Laboratory Tests: The following tests may be helpful in evaluating HPA axis suppression: Urinary free cortisol test ACTH stimulation test Carcinogenesis, Mutagenesis, and Impairment of Fertility: Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids. Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results. Pregnancy Category C: Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate and well-controlled studies in pregnant women on teratogenic effects from topically applied corticosteroids. Therefore topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time. Nursing Mothers: It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to nursing woman. Pediatric Use: Pediatric patients may demonstrate greater susceptibility to topical corticosteroid-induced hypothalamic-pituitary-adrenal (HPA) axis suppression and Cushings syndrome than mature patients because of larger skin surface area to body weight ratio. HPA axis suppression, Cushings syndrome, and intracranial hypertension have been reported in children receiving topical corticosteroids. Manifestations of adrenal suppression in children include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema. Administration of topical corticosteroids to children should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of children.
Citing DrugCentral © 2024. License