ADVERSE REACTIONS SECTION.
ADVERSE REACTIONS The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in approximate decreasing order of occurrence: burning, itching, irritation, dryness, folliculitis, hypertrichosis, acneiform eruptions, hypopigmentation, perioral dermatitis, allergic contact dermatitis, maceration of the skin, secondary infection, skin atrophy, striae and miliaria.To report SUSPECTED ADVERSE REACTIONS, contact Meda Pharmaceuticals Inc. at 1-866-210-5948 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.
Citing DrugCentral © 2024. License
CARCINOGENESIS & MUTAGENESIS & IMPAIRMENT OF FERTILITY SECTION.
Carcinogenesis, Mutagenesis, Impairment of Fertility Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids.Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results.
Citing DrugCentral © 2024. License
CLINICAL PHARMACOLOGY SECTION.
CLINICAL PHARMACOLOGY Topical corticosteroids share anti-inflammatory, antipruritic and vasoconstrictive actions.The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man.Pramoxine hydrochloride is surface or local anesthetic which is not chemically related to the caine types of local anesthetics. Its unique chemical structure is likely to minimize the danger of cross-sensitivity reactions in patients allergic to other local anesthetics. Pharmacokinetics The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings.Topical corticosteroids can be absorbed through normal intact skin. Inflammation and/or other disease processes in the skin increase the percutaneous absorption of topical corticosteroids. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be valuable therapeutic adjunct for treatment of resistant dermatoses. (See DOSAGE AND ADMINISTRATION.) Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.
Citing DrugCentral © 2024. License
CONTRAINDICATIONS SECTION.
CONTRAINDICATIONS Topical corticosteroid products are contraindicated in those patients with history of hypersensitivity to any of the components of the preparation.
Citing DrugCentral © 2024. License
DESCRIPTION SECTION.
DESCRIPTION Proctofoam(R) HC (hydrocortisone acetate 1% and pramoxine hydrochloride 1%) is topical aerosol foam for anal use containing hydrocortisone acetate 1% and pramoxine hydrochloride 1% in hydrophilic base containing cetyl alcohol, emulsifying wax, methylparaben, poly-oxyethylene-10-stearyl ether, propylene glycol, propylparaben, purified water, trolamine and inert propellants: isobutane and propane.Proctofoam(R) HC contains synthetic corticosteroid used as an anti-inflammatory/antipruritic agent and local anesthetic.Hydrocortisone acetateMolecular weight: 404.50. Solubility of hydrocortisone acetate in water: mg/100 mL.Chemical name: pregn-4-ene-3,20-dione, 21-(acetyloxy)-11,17-dihydroxy-,(11)-.Pramoxine hydrochloride Molecular weight: 329.86. Pramoxine hydrochloride is freely soluble in water. Chemical name: morpholine, 4-[3-(4-butoxyphenoxy) propyl]-, hydrochloride.. Hydrocortisone Acetate Structural Formula. Pramoxine Hydrochloride Structural Formula.
Citing DrugCentral © 2024. License
DOSAGE & ADMINISTRATION SECTION.
DOSAGE AND ADMINISTRATION Apply to affected area to times daily. Use the applicator supplied for anal administration. For perianal use, transfer small quantity to tissue and rub in gently.Directions for Use.1.Place cap on top of container. Shake foam container vigorously for 5-10 seconds before each use. Do not remove container cap during use of the product.2.Hold container upright on level surface and gently place the tip of the applicator onto the nose of the container cap. CONTAINER MUST BE HELD UPRIGHT TO OBTAIN PROPER FLOW OF MEDICATION.3.Pull plunger past the fill line on the applicator barrel.4.Hold the container and applicator at eye level. Place the index and middle fingers on the container cap flanges and the thumb beneath the container. Support the applicator with your other hand. Prime the container by pressing down firmly on flanges and then release. With initial priming, burst of air may come out of the container. It usually requires 1-2 pumps for foam to appear.5.To fill applicator barrel, press down firmly on cap flanges, hold for 1-2 seconds, and release. Wait 5-10 seconds to allow foam to expand in applicator barrel. Repeat until foam reaches fill line. It usually requires 3-4 pumps for foam to reach fill line. Remove applicator from container cap. Note: If foam goes beyond fill line, it will continue to expand and flow backwards resulting in foam build-up under cap.6.Hold applicator firmly by barrel, making sure thumb and middle finger are positioned securely underneath and resting against barrel wings. Place index finger over the plunger. Gently insert tip into anus. Once in place, push plunger to expel foam, then withdraw applicator. CAUTION: Do not insert any part of the aerosol container directly into the anus. Apply to anus only with enclosed applicator. Do not insert any part of the applicator past the anus into rectum.7.After each use, applicator parts should be pulled apart for thorough cleaning with warm water. Since some foam will appear under the cap, the cap and underlying tip should be pulled apart and rinsed to help prevent build-up of foam and possible blockage.. 1.Place cap on top of container. Shake foam container vigorously for 5-10 seconds before each use. Do not remove container cap during use of the product.. 2.Hold container upright on level surface and gently place the tip of the applicator onto the nose of the container cap. CONTAINER MUST BE HELD UPRIGHT TO OBTAIN PROPER FLOW OF MEDICATION.. 3.Pull plunger past the fill line on the applicator barrel.. 4.Hold the container and applicator at eye level. Place the index and middle fingers on the container cap flanges and the thumb beneath the container. Support the applicator with your other hand. Prime the container by pressing down firmly on flanges and then release. With initial priming, burst of air may come out of the container. It usually requires 1-2 pumps for foam to appear.. 5.To fill applicator barrel, press down firmly on cap flanges, hold for 1-2 seconds, and release. Wait 5-10 seconds to allow foam to expand in applicator barrel. Repeat until foam reaches fill line. It usually requires 3-4 pumps for foam to reach fill line. Remove applicator from container cap. Note: If foam goes beyond fill line, it will continue to expand and flow backwards resulting in foam build-up under cap.. 6.Hold applicator firmly by barrel, making sure thumb and middle finger are positioned securely underneath and resting against barrel wings. Place index finger over the plunger. Gently insert tip into anus. Once in place, push plunger to expel foam, then withdraw applicator. CAUTION: Do not insert any part of the aerosol container directly into the anus. Apply to anus only with enclosed applicator. Do not insert any part of the applicator past the anus into rectum.. 7.After each use, applicator parts should be pulled apart for thorough cleaning with warm water. Since some foam will appear under the cap, the cap and underlying tip should be pulled apart and rinsed to help prevent build-up of foam and possible blockage.
Citing DrugCentral © 2024. License
GENERAL PRECAUTIONS SECTION.
General Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushings syndrome, hyperglycemia, and glucosuria in some patients. Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings. Therefore, patients receiving large dose of potent topical steroid applied to large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application or to substitute less potent steroid.Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids. Pediatric patients may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity. (see PRECAUTIONS: Pediatric Use.)If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted.In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled.
Citing DrugCentral © 2024. License
GERIATRIC USE SECTION.
Geriatric Use Reported clinical experience has not identified differences in responses between the elderly and younger patients. In general, dose selection for an elderly patient should be cautious using the least amount compatible with an effective therapeutic regimen and reflecting the greater frequency of decreased hepatic, renal or cardiac function, and of concomitant disease or other drug therapy.
Citing DrugCentral © 2024. License
HOW SUPPLIED SECTION.
HOW SUPPLIED Proctofoam(R) HC is supplied in an aerosol container with special anal applicator. When used correctly, the aerosol container will deliver minimum of 14 applications.NDC 0037-6822-10 10 gStore upright at controlled room temperature 20-25C (68-77F). DO NOT REFRIGERATE.Distributed by: Meda Pharmaceuticals Inc. Somerset, New Jersey 08873-4120(c)2020 Mylan Specialty L.P.Proctofoam is registered trademark of Alaven Pharmaceutical LLC, Mylan company.IN-682210-03141135-0420.
Citing DrugCentral © 2024. License
INDICATIONS & USAGE SECTION.
INDICATIONS AND USAGE Proctofoam(R) HC is indicated for the relief of the inflammatory and pruritic manifestations of corticosteroid-responsive dermatoses of the anal region.
Citing DrugCentral © 2024. License
INSTRUCTIONS FOR USE SECTION.
PLEASE READ CAREFULLY BEFORE USINGPATIENT INSTRUCTIONS FOR proctofoam(R) HC(hydrocortisone acetate 1% and pramoxine hydrochloride 1%) TOPICAL AEROSOLKeep this insert. It containsimportant information aboutthe use of proctofoam(R) HC. Place cap on top of container. Shake foam container vigorously for 5-10 seconds before each use. Do not remove container cap during use of the product. Hold container upright on level surface and gently place the tip of the applicator onto the nose of the container cap. CONTAINER MUST BE HELD UPRIGHT TO OBTAIN PROPER FLOW OF MEDICATION. Pull plunger past the fill line on the applicator barrel. Hold the container and applicator at eye level. Place the index and middle fingers on the container cap flanges and the thumb beneath the container. Support the applicator with your other hand. Prime the container by pressing down firmly on flanges and then release. With initial priming, burst of air may come out of the container. It usually requires 1-2 pumps for foam to appear. To fill applicator barrel, press down firmly on cap flanges, hold for 1-2 seconds, and release. Wait 5-10 seconds to allow foam to expand in applicator barrel. Repeat until foam reaches fill line. It usually requires 3-4 pumps for foam to reach fill line. Remove applicator from container cap. Note: If foam goes beyond fill line, it will continue to expand and flow backwards resulting in foam build-up under cap. Hold applicator firmly by barrel, making sure thumb and middle finger are positioned securely underneath and resting against barrel wings. Place index finger over the plunger. Gently insert tip into anus. Once in place, push plunger to expel foam, then withdraw applicator. CAUTION: Do not insert any part of the aerosol container directly into the anus. Apply to anus only with enclosed applicator. Do not insert any part of the applicator past the anus into rectum. After each use, applicator parts should be pulled apart for thorough cleaning with warm water. Since some foam will appear under the cap, the cap and underlying tip should be pulled apart and rinsed to help prevent build-up of foam and possible blockage.Distributed by:Meda Pharmaceuticals Inc.Somerset, New Jersey 08873-4120Proctofoam is registered trademark of Alaven Pharmaceutical LLC, Mylan company.To report SUSPECTED ADVERSE REACTIONS, contact Meda Pharmaceuticals Inc. at 1-866-210-5948 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.IS-682210-03141134-0420. Place cap on top of container. Shake foam container vigorously for 5-10 seconds before each use. Do not remove container cap during use of the product. 2 Hold container upright on level surface and gently place the tip of the applicator onto the nose of the container cap. CONTAINER MUST BE HELD UPRIGHT TO OBTAIN PROPER FLOW OF MEDICATION.. Pull plunger past the fill line on the applicator barrel.. Hold the container and applicator at eye level. Place the index and middle fingers on the container cap flanges and the thumb beneath the container. Support the applicator with your other hand. Prime the container by pressing down firmly on flanges and then release. With initial priming, burst of air may come out of the container. It usually requires 1-2 pumps for foam to appear.. To fill applicator barrel, press down firmly on cap flanges, hold for 1-2 seconds, and release. Wait 5-10 seconds to allow foam to expand in applicator barrel. Repeat until foam reaches fill line. It usually requires 3-4 pumps for foam to reach fill line. Remove applicator from container cap. Note: If foam goes beyond fill line, it will continue to expand and flow backwards resulting in foam build-up under cap.. Hold applicator firmly by barrel, making sure thumb and middle finger are positioned securely underneath and resting against barrel wings. Place index finger over the plunger. Gently insert tip into anus. Once in place, push plunger to expel foam, then withdraw applicator. CAUTION: Do not insert any part of the aerosol container directly into the anus. Apply to anus only with enclosed applicator. Do not insert any part of the applicator past the anus into rectum.. After each use, applicator parts should be pulled apart for thorough cleaning with warm water. Since some foam will appear under the cap, the cap and underlying tip should be pulled apart and rinsed to help prevent build-up of foam and possible blockage.. Instructions for Use Figure A. Instructions for Use Figure 1. Instructions for Use Figure 2. Instructions for Use Figure 3. Instructions for Use Figure 4. Instructions for Use Figure 5. Instructions for Use Figure 6.
Citing DrugCentral © 2024. License
LABORATORY TESTS SECTION.
Laboratory Tests The following tests may be helpful in evaluating the HPA axis suppression:Urinary free cortisol testACTH stimulation test.
Citing DrugCentral © 2024. License
NURSING MOTHERS SECTION.
Nursing Mothers It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to nursing woman.
Citing DrugCentral © 2024. License
OVERDOSAGE SECTION.
OVERDOSAGE Topically applied corticosteroids can be absorbed in sufficient amounts to produce systemic effects. (See PRECAUTIONS.).
Citing DrugCentral © 2024. License
PACKAGE LABEL.PRINCIPAL DISPLAY PANEL.
PRINCIPAL DISPLAY PANEL 10 . NDC 0037-6822-10STORE UPRIGHTproctofoam(R) HC(hydrocortisone acetate 1% andpramoxine hydrochloride 1%)topical aerosolRx Only10 net wtDescription proctofoam(R) HC (hydrocortisone acetate 1% andpramoxine hydrochloride 1%) is topical aerosol foam foranal use containing hydrocortisone acetate 1% andpramoxine hydrochloride 1% in hydrophilic basecontaining cetyl alcohol, emulsifying wax, methylparabenpolyoxyethylene-10-stearyl ether, propylene glycolpropylparaben, purified water, trolamine, and inertpropellants: isobutane and propane.Dosage: Apply to effected areas to times daily. Usethe applicator supplied for anal administration. Forperianal use, transfer small quantity to tissue and rubgently. See patient instructions (inside) for fulldirections for use. Please see package insert forcomplete prescribing information.Caution: Do not insert any part of the aerosol containerdirectly into the anus. Apply to anus only with theenclosed applicator. Do not insert any part of applicatorpast the anus into rectum.WARNINGS: Contents of the container are underpressure. Do not burn or puncture the aerosol container.Do not store at temperatures above 120F (49C).KEEP OUT OF REACH OF CHILDREN.Store upright at controlled room temperature20 25C (68 77F).DO NOT REFRIGERATE.117604-0520 UC-682210-04Distributed by:Meda Pharmaceuticals IncSomerset, New Jersey08873-4120(C)2020 Mylan Specialty L.P.Proctofoam is registeredtrademark ofAlaven Pharmaceutical LLC,a Mylan company.. Proctofoam HC Topical Aerosol Carton.
Citing DrugCentral © 2024. License
PEDIATRIC USE SECTION.
Pediatric Use Pediatric patients may demonstrate greater susceptibility to topical corticosteroid-induced HPA axis suppression and Cushings syndrome than mature patients because of larger skin surface area to body weight ratio.Hypothalamic-pituitary-adrenal (HPA) axis suppression, Cushings syndrome, and intracranial hypertension have been reported in pediatric patients receiving topical corticosteroids. Manifestations of adrenal suppression in pediatric patients include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema. Administration of topical corticosteroids to pediatric patients should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of pediatric patients.
Citing DrugCentral © 2024. License
PHARMACOKINETICS SECTION.
Pharmacokinetics The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings.Topical corticosteroids can be absorbed through normal intact skin. Inflammation and/or other disease processes in the skin increase the percutaneous absorption of topical corticosteroids. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be valuable therapeutic adjunct for treatment of resistant dermatoses. (See DOSAGE AND ADMINISTRATION.) Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.
Citing DrugCentral © 2024. License
PRECAUTIONS SECTION.
PRECAUTIONS General Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushings syndrome, hyperglycemia, and glucosuria in some patients. Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings. Therefore, patients receiving large dose of potent topical steroid applied to large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application or to substitute less potent steroid.Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids. Pediatric patients may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity. (see PRECAUTIONS: Pediatric Use.)If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted.In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled. Information for the Patient Patients using topical corticosteroids should receive the following information and instructions:1.This medication is to be used as directed by the physician. It is for anal or perianal use only. Avoid contact with eyes.2.Be advised not to use this medication for any disorder other than for which it has been prescribed.3.Report any signs of adverse reactions.. 1.This medication is to be used as directed by the physician. It is for anal or perianal use only. Avoid contact with eyes.. 2.Be advised not to use this medication for any disorder other than for which it has been prescribed.. 3.Report any signs of adverse reactions.. Laboratory Tests The following tests may be helpful in evaluating the HPA axis suppression:Urinary free cortisol testACTH stimulation test Carcinogenesis, Mutagenesis, Impairment of Fertility Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids.Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results.. Pregnancy Teratogenic Effects. Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate, well-controlled studies of teratogenic effects from topically applied corticosteroids in pregnant women. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.. Nursing Mothers It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to nursing woman.. Pediatric Use Pediatric patients may demonstrate greater susceptibility to topical corticosteroid-induced HPA axis suppression and Cushings syndrome than mature patients because of larger skin surface area to body weight ratio.Hypothalamic-pituitary-adrenal (HPA) axis suppression, Cushings syndrome, and intracranial hypertension have been reported in pediatric patients receiving topical corticosteroids. Manifestations of adrenal suppression in pediatric patients include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema. Administration of topical corticosteroids to pediatric patients should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of pediatric patients.. Geriatric Use Reported clinical experience has not identified differences in responses between the elderly and younger patients. In general, dose selection for an elderly patient should be cautious using the least amount compatible with an effective therapeutic regimen and reflecting the greater frequency of decreased hepatic, renal or cardiac function, and of concomitant disease or other drug therapy.
Citing DrugCentral © 2024. License
PREGNANCY SECTION.
Pregnancy Teratogenic Effects. Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate, well-controlled studies of teratogenic effects from topically applied corticosteroids in pregnant women. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.
Citing DrugCentral © 2024. License
SPL UNCLASSIFIED SECTION.
Information for the Patient Patients using topical corticosteroids should receive the following information and instructions:1.This medication is to be used as directed by the physician. It is for anal or perianal use only. Avoid contact with eyes.2.Be advised not to use this medication for any disorder other than for which it has been prescribed.3.Report any signs of adverse reactions.. 1.This medication is to be used as directed by the physician. It is for anal or perianal use only. Avoid contact with eyes.. 2.Be advised not to use this medication for any disorder other than for which it has been prescribed.. 3.Report any signs of adverse reactions.
Citing DrugCentral © 2024. License
TERATOGENIC EFFECTS SECTION.
Teratogenic Effects. Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate, well-controlled studies of teratogenic effects from topically applied corticosteroids in pregnant women. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.
Citing DrugCentral © 2024. License
WARNINGS SECTION.
WARNINGS Do not insert any part of the aerosol container directly into the anus. Avoid contact with the eyes. Contents of the container are under pressure. Do not burn or puncture the aerosol container. Do not store at temperatures above 120F (49C). If there is no evidence of clinical improvement within two or three weeks after starting Proctofoam(R) HC therapy, or if the patients condition worsens, discontinue the drug. Keep this and all medicines out of the reach of children.
Citing DrugCentral © 2024. License