PACKAGE LABEL.PRINCIPAL DISPLAY PANEL.


BAG LABEL. Collection Bag LabelHPC, Cord BloodANTICOAGULANT CITRATE PHOSPHATE DEXTROSE SOLUTION35 ml Anticoagulant Citrate Phosphate Dextrose Solution for collection of up to 210 ml of umbilical cord blood. Each 35 ml of CPD solution contains 0.921 sodium citrate (dihydrate), USP; 0.893 dextrose (monohydrate), USP; 0.114 citric acid (monohydrate), USP; and 0.078 monobasic sodium phosphate (monohydrate), USP. Use only if solution is clear.Warning: This product may transmit infectious agents. Sterile, nonpyrogenic fluid path. Do not irradiate. Rx only. Code 791-08. Issued August 2010, 147791082. Collection Bag Label.

PRECAUTIONS SECTION.


GENERAL PRECAUTIONS. Do not use if the package is damaged or seal is incomplete. Use only if solution is clear.Sealing should be done in manner that avoids fluid splatter.Always dispose of blood-contaminated products in manner consistent with established BIOHAZARD safety procedures.

WARNINGS SECTION.


WARNINGS. Do not irradiate collected cord blood or components.Making multiple punctures of the umbilical cord to increase collection volume may increase the risk of contamination.

DESCRIPTION SECTION.


ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE SOLUTION (CPD). Sterile, non-pyrogenic fluid path. Sterilized by steam.Rx only.This product is free of natural rubber latex.

HOW SUPPLIED SECTION.


HOW SUPPLIED. The Collection Unit inside the overwrap pouch, within the foil envelope, are sterile and acceptable for use in sterile field if pouch is unopened and undamaged.

INDICATIONS & USAGE SECTION.


INDICATIONS AND USAGE. For collection of up to 210 ml of umbilical cord blood. Use aseptic technique.. Sterile Exterior. Contents inside overwrap pouch, within the foil envelope, are sterile and acceptable for use in sterile field if pouch is unopened and undamaged; visual inspection to confirm the integrity of overwrap pouch should be performed.

INFORMATION FOR PATIENTS SECTION.


INFORMATION FOR PATIENTS. Medsep Corporation, Subsidiary of Pall Corp., Covina, CA 91722, USAVisit us at www.pall.com/medicalFor Pall customer service, call: 1.800.645.6578DonorCare is registered trademark of ITL Corporation, Canberra, Australia. Produced under license from ThermoGenesis Corp.. Instructions for Use. 1. Ensure DonorCare(R) Needle Guard (DCNG) is positioned on the tubing between the needle hub and Pinch Clamp. Engage Pinch Clamp. Ensure tethered cap is placed securely on the air vent.2. Using aseptic technique, insert needle into umbilical vein, disengage Pinch Clamp to collect cord blood, mixing frequently, according to standard procedures.3. Upon completion of collection, engage Pinch Clamp then withdraw needle from umbilical vein. Slide the DCNG midway over the needle hub. While holding the sides of DCNG near front, grasp tubing and pull smoothly, pulling needle into the DCNG until it locks into place. Confirm that needle is locked by listening for the second click as the needle is drawn into the DCNG. Ensure that tubing cannot be pulled through DCNG.4. Place the bag on work surface. While holding the tubing above the bag, open the tethered cap on the air vent. Allow the blood to drain from the tubing into the bag.5. When the tubing has been drained, hold tubing vertical and seal tubing directly below the Y-piece with air vent.6. Detach and discard needle, DCNG, Pinch Clamp, Air Vent and tubing according to standard procedures.7. Determine amount of anticoagulated blood collected. If required, add sedimenting agent to CPD anticoagulated blood through Sample Port using syringe according to standard procedures.8. Mix well. Take care to strip and mix any blood in tubing.9. Load bag into centrifuge cup. It is suggested that means of support is used to prevent bag from collapsing and to reduce wrinkles.10. Centrifuge according to standard procedures to obtain mononuclear cell-rich plasma.. Cord Blood Collection Unit.