INDICATIONS & USAGE SECTION.
INDICATIONS AND USAGE. SYNALAR(R) Cream is indicated for the relief of the inflammatory and pruritic manifestations of corticosteriod-responsive dermatoses.
Citing DrugCentral © 2024. License
ADVERSE REACTIONS SECTION.
ADVERSE REACTIONS. The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in an approximate decreasing order of occurrence:Burning Hypertrichosis Maceration of the skin Itching Acneiform eruptions Secondary infection Irritation Hypopigmentation Skin atrophy Dryness Perioral dermatitis Striae Folliculitis Allergic contact dermatitis Miliaria.
Citing DrugCentral © 2024. License
CARCINOGENESIS & MUTAGENESIS & IMPAIRMENT OF FERTILITY SECTION.
Carcinogenesis, Mutagenesis, and Impairment of Fertility. Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids.Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results.
Citing DrugCentral © 2024. License
CLINICAL PHARMACOLOGY SECTION.
CLINICAL PHARMACOLOGY. Topical corticosteroids share anti-inflammatory, anti-pruritic and vasoconstrictive actions.. The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man.. Pharmacokinetics. The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings.Topical corticosteroids can be absorbed from normal intact skin. Inflammation and/or other disease processes in the skin increase percutaneous absorption. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be valuable therapeutic adjunct for treatment of resistant dermatoses (see DOSAGE AND ADMINISTRATION).Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.
Citing DrugCentral © 2024. License
CONTRAINDICATIONS SECTION.
CONTRAINDICATIONS. Topical corticosteroids are contraindicated in those patients with history of hypersensitivity to any of the components of the preparation.
Citing DrugCentral © 2024. License
DESCRIPTION SECTION.
DESCRIPTION. SYNALAR(R) (fluocinolone acetonide) Cream 0.025% is intended for topical administration. The active component is the corticosteroid fluocinolone acetonide, which has the chemical name pregna-1,4-diene-3,20-dione,6,9-difluoro-11,21-dihydroxy-16,17-[(1-methylethylidene)bis (oxy)]-,(6,11,16)-. It has the following chemical structure:SYNALAR(R) Cream contains fluocinolone acetonide 0.25 mg/g in water-washable aqueous base of butylated hydroxytoluene, cetyl alcohol, citric acid, edetate disodium, methylparaben and propylparaben (preservatives), mineral oil, polyoxyl 20 cetostearyl ether, propylene glycol, simethicone, stearyl alcohol, water (purified) and white beeswax.. Chemical Structure.
Citing DrugCentral © 2024. License
DOSAGE & ADMINISTRATION SECTION.
DOSAGE AND ADMINISTRATION. SYNALAR(R) Cream is generally applied to the affected area as thin film from two to four times daily depending on the severity of the condition. In hairy sites, the hair should be parted to allow direct contact with the lesion.Occlusive dressing may be used for the management of psoriasis or recalcitrant conditions. Some plastic films may be flammable and due care should be exercised in their use. Similarly, caution should be employed when such films are used on children or left in their proximity, to avoid the possibility of accidental suffocation.If an infection develops, the use of the occlusive dressings should be discontinued and appropriate antimicrobial therapy instituted.
Citing DrugCentral © 2024. License
GENERAL PRECAUTIONS SECTION.
General. Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushings syndrome, hyperglycemia, and glucosuria in some patients.Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings.Therefore, patients receiving large dose of potent topical steroid applied to large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application, or to substitute less potent steroid.Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids.Children may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity (see PRECAUTIONS--Pediatric Use).If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted.As with any topical corticosteroid product, prolonged use may produce atrophy of the skin and subcutaneous tissues. When used on intertriginous or flexor areas, or on the face, this may occur even with short-term use.In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled.
Citing DrugCentral © 2024. License
HOW SUPPLIED SECTION.
HOW SUPPLIED. SYNALAR(R) (fluocinolone acetonide) Cream 0.025% is supplied in 60 Tube NDC 43538-900-60 120 Tube NDC 43538-900-12. 60 Tube NDC 43538-900-60. 120 Tube NDC 43538-900-12. STORAGE. Store at room temperature 15-25C (59-77F); avoid freezing and excessive heat above 40C (104F).
Citing DrugCentral © 2024. License
INFORMATION FOR PATIENTS SECTION.
Information for the Patient. Patients using topical corticosteroids should receive the following information and instructions:This medication is to be used as directed by the physician. It is for external use only. Avoid contact with the eyes.Patients should be advised not to use this medication for any disorder other than that for which it was prescribed.The treated skin area should not be bandaged or otherwise covered or wrapped as to be occlusive unless directed by the physician.Patients should report any signs of local adverse reactions, especially under occlusive dressing.Parents of pediatric patients should be advised not to use tight-fitting diapers or plastic pants on child being treated in the diaper area, as these garments may constitute occlusive dressings.. This medication is to be used as directed by the physician. It is for external use only. Avoid contact with the eyes.. Patients should be advised not to use this medication for any disorder other than that for which it was prescribed.. The treated skin area should not be bandaged or otherwise covered or wrapped as to be occlusive unless directed by the physician.. Patients should report any signs of local adverse reactions, especially under occlusive dressing.. Parents of pediatric patients should be advised not to use tight-fitting diapers or plastic pants on child being treated in the diaper area, as these garments may constitute occlusive dressings.
Citing DrugCentral © 2024. License
LABORATORY TESTS SECTION.
Laboratory Tests. The following tests may be helpful in evaluating the HPA axis suppression: Urinary free cortisol test ACTH stimulation test. Urinary free cortisol test. ACTH stimulation test.
Citing DrugCentral © 2024. License
MECHANISM OF ACTION SECTION.
The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man.
Citing DrugCentral © 2024. License
NURSING MOTHERS SECTION.
Nursing Mothers. It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to nursing woman.
Citing DrugCentral © 2024. License
OVERDOSAGE SECTION.
OVERDOSAGE. Topically applied corticosteroids can be absorbed in sufficient amounts to produce systemic effects (see PRECAUTIONS).
Citing DrugCentral © 2024. License
PACKAGE LABEL.PRINCIPAL DISPLAY PANEL.
PRINCIPAL DISPLAY PANEL 120 Tube Carton. Rx OnlyNDC 43538-900-12SYNALAR(R)(fluocinolone acetonide)Cream, 0.025%For Topical Use OnlyNot For Ophthalmic Use120 gMEDIMETRIKSPHARMACEUTICALS, INC.. PRINCIPAL DISPLAY PANEL 120 Tube Carton.
Citing DrugCentral © 2024. License
PEDIATRIC USE SECTION.
Pediatric Use. Pediatric patients may demonstrate greater susceptibility to topical corticosteroidinduced hypothalmic-pituitary-adrenal (HPA) axis suppression and Cushings syndrome than mature patients because of larger skin surface area to body weight ratio.HPA axis suppression, Cushings syndrome, and intracranial hypertension have been reported in children receiving topical corticosteroids. Manifestations of adrenal suppression in children include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema.Administration of topical corticosteroids to children should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of children.
Citing DrugCentral © 2024. License
PHARMACOKINETICS SECTION.
Pharmacokinetics. The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings.Topical corticosteroids can be absorbed from normal intact skin. Inflammation and/or other disease processes in the skin increase percutaneous absorption. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be valuable therapeutic adjunct for treatment of resistant dermatoses (see DOSAGE AND ADMINISTRATION).Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.
Citing DrugCentral © 2024. License
PRECAUTIONS SECTION.
PRECAUTIONS. General. Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushings syndrome, hyperglycemia, and glucosuria in some patients.Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings.Therefore, patients receiving large dose of potent topical steroid applied to large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application, or to substitute less potent steroid.Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids.Children may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity (see PRECAUTIONS--Pediatric Use).If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted.As with any topical corticosteroid product, prolonged use may produce atrophy of the skin and subcutaneous tissues. When used on intertriginous or flexor areas, or on the face, this may occur even with short-term use.In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled.. Information for the Patient. Patients using topical corticosteroids should receive the following information and instructions:This medication is to be used as directed by the physician. It is for external use only. Avoid contact with the eyes.Patients should be advised not to use this medication for any disorder other than that for which it was prescribed.The treated skin area should not be bandaged or otherwise covered or wrapped as to be occlusive unless directed by the physician.Patients should report any signs of local adverse reactions, especially under occlusive dressing.Parents of pediatric patients should be advised not to use tight-fitting diapers or plastic pants on child being treated in the diaper area, as these garments may constitute occlusive dressings.. This medication is to be used as directed by the physician. It is for external use only. Avoid contact with the eyes.. Patients should be advised not to use this medication for any disorder other than that for which it was prescribed.. The treated skin area should not be bandaged or otherwise covered or wrapped as to be occlusive unless directed by the physician.. Patients should report any signs of local adverse reactions, especially under occlusive dressing.. Parents of pediatric patients should be advised not to use tight-fitting diapers or plastic pants on child being treated in the diaper area, as these garments may constitute occlusive dressings.. Laboratory Tests. The following tests may be helpful in evaluating the HPA axis suppression: Urinary free cortisol test ACTH stimulation test. Urinary free cortisol test. ACTH stimulation test. Carcinogenesis, Mutagenesis, and Impairment of Fertility. Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids.Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results.. Pregnancy Category C. Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate and well-controlled studies in pregnant women on teratogenic effects from topically applied corticosteroids. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.. Nursing Mothers. It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to nursing woman.. Pediatric Use. Pediatric patients may demonstrate greater susceptibility to topical corticosteroidinduced hypothalmic-pituitary-adrenal (HPA) axis suppression and Cushings syndrome than mature patients because of larger skin surface area to body weight ratio.HPA axis suppression, Cushings syndrome, and intracranial hypertension have been reported in children receiving topical corticosteroids. Manifestations of adrenal suppression in children include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema.Administration of topical corticosteroids to children should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of children.
Citing DrugCentral © 2024. License
PREGNANCY SECTION.
Pregnancy Category C. Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate and well-controlled studies in pregnant women on teratogenic effects from topically applied corticosteroids. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.
Citing DrugCentral © 2024. License
SPL UNCLASSIFIED SECTION.
for initiation of therapy in inflammatory dermatoses. Rx Only.
Citing DrugCentral © 2024. License
STORAGE AND HANDLING SECTION.
STORAGE. Store at room temperature 15-25C (59-77F); avoid freezing and excessive heat above 40C (104F).
Citing DrugCentral © 2024. License